ELEM-014 THREE-PHASE ELECTRICITY METERING UNIT
ELEM-014 is a smart direct-connected commercial electricity meter suitable for low voltage applications.
The meter provides extensive functionality in key areas of metering: power quality, anti-tampering, security, billing data protection and outage support.
This version is intended for indoor installation.
The meter provides extensive functionality in key areas of metering: power quality, anti-tampering, security, billing data protection and outage support.
This version is intended for indoor installation.
ELEM-014 THREE-PHASE ELECTRICITY METERING UNIT
PURPOSE
– measurement of active, reactive energy for forward and reverse directions in three-phase AC circuits;– operating autonomously or as part of the AMI.
MEASURED PARAMETERS
– active and reactive electrical energy of forward and reverse directions;– active, reactive and apparent demand for each phase and total for three phases;
– RMS (effective) current and voltage values for each phase;
– RMS (effective) values of linear voltages;
– power factor for each phase and total;
– instrumentation values (U, I, f, ...).
INTERFACES AND COMMUNICATION
– Optical port;– RS-485 (optional);
– PLC (optional);
– ZigBee 2.4 GHz with internal/external antenna (optional);
– Self-organizing mesh network for PLC and ZigBee interfaces;
– 868 MHz RF with internal/external antenna (optional);
– 1 mechanical relay output (optional);
– One pulse input (optional).
ANTI-TAMPER CAPABILITIES
– configurable outage capability (by remote command or by exceeding internal setting);– subscriber disconnection when the voltage is exceeded, or if there is an external magnetic field, or if the temperature inside is critically high;
– visual magnetic field impact indicator;
– main/terminal cover removal detection;
– anti-tamper built-in 3D magnetic field sensor;
– self-diagnostics.
Description
PURPOSE
– measurement of active, reactive energy for forward and reverse directions in three-phase AC circuits;– operating autonomously or as part of the AMI.
MEASURED PARAMETERS
– active and reactive electrical energy of forward and reverse directions;– active, reactive and apparent demand for each phase and total for three phases;
– RMS (effective) current and voltage values for each phase;
– RMS (effective) values of linear voltages;
– power factor for each phase and total;
– instrumentation values (U, I, f, ...).
INTERFACES AND COMMUNICATION
– Optical port;– RS-485 (optional);
– PLC (optional);
– ZigBee 2.4 GHz with internal/external antenna (optional);
– Self-organizing mesh network for PLC and ZigBee interfaces;
– 868 MHz RF with internal/external antenna (optional);
– 1 mechanical relay output (optional);
– One pulse input (optional).
ANTI-TAMPER CAPABILITIES
– configurable outage capability (by remote command or by exceeding internal setting);– subscriber disconnection when the voltage is exceeded, or if there is an external magnetic field, or if the temperature inside is critically high;
– visual magnetic field impact indicator;
– main/terminal cover removal detection;
– anti-tamper built-in 3D magnetic field sensor;
– self-diagnostics.